home *** CD-ROM | disk | FTP | other *** search
/ Tech Arsenal 1 / Tech Arsenal (Arsenal Computer).ISO / tek-07 / blts893.zip / ACAD12.TXT < prev    next >
Text File  |  1993-05-21  |  24KB  |  486 lines

  1. COMPATIBILITY BULLETIN
  2. 5.13.93 AUTOCAD386 MWF 
  3. CAD SOFTWARE: AutoCAD 386 (Release 10C10, Release 11 & Release 12),
  4. Autodesk, Inc.
  5.  
  6.  
  7. Compatibility Statement:
  8. AutoCAD 386 (Release 10C10, Release 11 & Release 12) is compatible
  9. with LANtastic NOS v4.xx and v5.xx. 
  10.  
  11. Basic Guidelines for using AutoCAD 386 with LANtastic:
  12. 1. AutoCAD 386 is a very processor-time intensive application that
  13. runs in protected mode on an 386 or 486 computer. It can access up to
  14. 4 Gigabytes of memory (either in RAM or virtual disk space), however
  15. the program uses between 80K and 250K of conventional RAM when
  16. loaded, depending on the version of the Phar Lap 386|DOS-Extender
  17. being used.  No problems were found from loading the network drivers
  18. into high memory with a memory manager.
  19.  
  20. 2. Using an AutoCAD 386 workstation as a server for sharing a plotter
  21. or printer-plotter is not recommended.  Performance of AutoCAD 386
  22. can be severely reduced by background plotter or printer-plotter
  23. despooling (generally seen as slow or jerky cross-hair movement). The
  24. ideal AutoCAD network configuration would include a dedicated server
  25. with harddrive for file access and printer ports for the plotter(s)
  26. and printer-plotter(s), thus allowing the AutoCAD workstations to
  27. have 100% of their own processor time available for AutoCAD 386
  28. functions. The next best solution is to place the shared
  29. printer/plotter devices on a server that is not running AutoCAD.
  30.  
  31. 3. Set FCBS=16,8 and FILES=40 in CONFIG.SYS on workstations running
  32. AutoCAD 386. NOTE: If AutoCAD 10 (DOS) will be used on the same
  33. workstation running under DOS 4.01, set FCBS=48,8 in CONFIG.SYS.
  34.  
  35. 4. Protected-mode video Display List Drivers are available in ADI
  36. format to use with AutoCAD 386 and work very well. Some real-mode
  37. DLD's are also available and no compatibility problems have been
  38. reported with LANtastic. Switching between real and protected-mode
  39. can degrade performance, so using a protected-mode video driver is
  40. recommended for maximum performance.
  41.  
  42. 5. AutoCAD 386 loads entirely into RAM so there is no benefit to
  43. using a ramdisk [as far as AutoCAD 386 is concerned]. There are no
  44. overlay files, and if the workstation has enough RAM available, there
  45. will be only minimal disk access when editing a drawing. A small disk
  46. cache (256K) will improve performance when AutoCAD 386 is paging to
  47. disk. However, don't give too much memory to utilities like ramdisks
  48. or caching as it will take memory away from AutoCAD and performance
  49. can suffer.  Autodesk recommends a minimum memory configuration of 4
  50. Meg RAM for Release 10C10 and Release 11, and 8 Meg RAM for Release
  51. 12.  More memory will improve performance when editing large
  52. drawings.
  53.  
  54. 6.  Configure each AutoCAD workstation to have a unique network node
  55. name.  In release 10C10 or Release 11: select "5. Configure AutoCAD",
  56. (from the AutoCAD main menu), "8. Configure operating parameters",
  57. "6. Network node name" and enter a three character name unique to
  58. each workstation.  In Release 12: run "CONFIG" from the "Command: "
  59. prompt and select "Configure operating parameters", "6. Network node
  60. name".  This will make sure that two nodes do not use the same name
  61. for temporary files or for file locking.
  62.  
  63. 7. If plotter or printer-plotter performance is slow, or pauses
  64. intermittently, on an AutoCAD 386 workstation/server that is sharing
  65. a plotter, increase the CPS to the plotter (using the max of 32767 is
  66. OK, but the tradeoff is poor AutoCAD 386 performance during the
  67. despooling function). 
  68.  
  69. NOTE: The only way to eliminate the performance degradation of a
  70. server running AutoCAD 386 during plotting or printer-plotting is to
  71. have the server not running AutoCAD during the despooling -function.
  72. See note 2 above.
  73.  
  74. 8. To share a plotter or printer-plotter, AutoCAD must output to
  75. file. The important item to keep in mind is that AutoCAD 386 never
  76. communicates with the plotter (or printer-plotter), instead, it
  77. outputs to a file on disk. The network then copies this file to the
  78. printer or plotter. Configure AutoCAD 386 to plot to a file, set the
  79. filename to the name of the port that is redirected to @PLOTTER (or
  80. @PRINTER). Set the LPT TIMEOUT to 0 (zero).  If using Release 11 or
  81. 12, see the additional notes below on using the AUTOSPOOL feature.
  82.  
  83. 9.  The recommended serial communication protocol between the network
  84. and the plotter (or printer) is 9600, 8, 1, N, using XON/XOFF flow
  85. control. Some plotters that will only accept HARDWARE flow control
  86. require a HARDWARE cable - a straight-thru serial cable will not
  87. allow HARDWARE flow control communications. The next best protocol is
  88. 9600, 7, 1, E, XON/XOFF. The plotter and @PLOTTER shared resource (in
  89. NET_MGR) should be configured exactly the same.
  90.  
  91. NOTE: If the plotter does not automatically go OFF-LINE at the
  92. completion of a plot, it is recommended to edit the "Setup String"
  93. for @PLOTTER (located in NET_MGR, Shared Resources Management) to
  94. include the ASCII or <ESC> codes needed to take the plotter off-line
  95. at the start of a plot to allow for paper changes. If this is not
  96. done, it will be possible for multiple plot jobs in the spooler to be
  97. plotted over the same sheet of paper. If the plotter has an automatic
  98. paper feeder/cutter, this is not necessary.
  99.  
  100. 10. AutoCAD 386 Release 11 and Release 12 have a file-locking feature
  101. that is software selectable and will prevent multiple access to a
  102. drawing file.  Refer to the additional notes on Release 11 and
  103. Release 12 in the next section.
  104.  
  105. ** Memory Managers:
  106. 1. AutoCAD 386 can be configured to use either Extended or Expanded
  107. memory (depending on the Phar Lap 386|DOS-Extender being used).   If
  108. the memory manager is not VCPI compliant, configure all memory as
  109. Extended; if it is VCPI compliant, configure all memory as Expanded. 
  110. QEMM386, 386 to the MAX and MS-DOS's HIMEM.SYS in combination with
  111. EMM386.EXE will provide VCPI-compliant EMS memory.  HIMEM.SYS that
  112. comes with MS-DOS 5.0 creates XMS which is not VCPI compliant and
  113. should not be used with AutoCAD 386 Release 10C10 unless EMM386.EXE
  114. is also being loaded (NOTE: Phar Lap 386|DOS-Extender version 2.6
  115. (supplied with Release 11C2) and higher support XMS memory. If you
  116. are running Phar Lap 386|DOS-Extender v2.6, then XMS (HIMEM.SYS
  117. without EMM386.EXE) can be used. If there is any EMS available, all
  118. XMS will be ignored.)  Consult the AutoCAD 386 Installation and
  119. Performance Guide for more information on memory configuration.
  120.  
  121. 2. All network drivers can be loaded into high memory using the
  122. utilities provided with the above memory managers. There is no
  123. network performance impact loading the network drivers into high
  124. memory versus conventional memory.
  125.  
  126. 3. The Phar Lap 386|DOS-Extender's swap file can be located on a
  127. redirected drive.  For example, "CFIG386 ACAD -minswfsize 4000000 -
  128. swapdir E:\TEMP" will create a minimum swap file size of 4 Meg and
  129. place the file in the E:\TEMP directory. Alternately, CFIGPHAR.EXE
  130. provides a menu program for changing the Phar Lap 386|DOS-Extender
  131. switches.  Refer to the AutoCAD 386 Installation and Performance
  132. Guide for details on the specific Phar Lap 386|DOS-Extender version.
  133. If you have a multi-user license, do not forget to remove the read-
  134. only attribute on ACAD.EXE before, and reset it after, executing this
  135. command.
  136.  
  137. ** NOS Notes:
  138. A new feature starting with NOS 4.10, called "Immediate Despooling",
  139. can reduce printing and plotting time. To enable this new feature,
  140. run NET_MGR, select "Shared Resources Management" and enable
  141. "Immediate Despooling". Set "Despool Timeout" to 0 (zero - which will
  142. display as "DISABLED"). This is especially important to set the
  143. despool timeout to zero for plotters and postscript printers. This
  144. must be set individually for each printer or plotter resource in
  145. "Shared Resources Management".
  146.  
  147. ** Additional Notes on Release 11:
  148. 1. AutoCAD 386 Release 11 has two environment variables that can be
  149. used to create and send spooled plot files to a redirected plotter or
  150. printer-plotter automatically using the AUTOSPOOL feature. The
  151. recommended configuration is as follows:
  152.  
  153.     1)      Create a directory under the ACAD11 directory called TEMP
  154.             (C:\ACAD11\TEMP). 
  155.     2)      Configure AutoCAD 386-11 to put temporary files and the
  156.             SPOOLED print/plot files there as follows:
  157.         A)       From the AutoCAD main menu, select "5. Configure AutoCAD". 
  158.         B)       Select "5. Configure plotter" and "6. Configure printer
  159.                  plotter". Keep the same plotter and printer,
  160.         C)       Select "YES" when asked to output to a file.
  161.         D)       Select "8. Configure operating parameters."
  162.             A) Select "3. Default plot file name", enter "AUTOSPOOL". 
  163.             (NOTE: "AUTOSPOOL" must be in all capital letters.)
  164.             B) Select "4. Plot spooler directory", enter
  165.             "C:\ACAD11\TEMP\".
  166.         E)       Save the changes and exit the configuration menu.
  167.     3)      If you are using a batch file to load AutoCAD 386-11, put the
  168.             following lines in that batch file (otherwise put them in the
  169.             AUTOEXEC.BAT file on each node). (NOTE: the "%%s" MUST BE
  170.             LOWER CASE.)
  171.  
  172.         SET ACADPLCMD=NET PRINT %%s COM2  (Port redirected to @PLOTTER)
  173.         SET ACADPPCMD=NET PRINT/BINARY %%s LPT1 (Port redirected to
  174.         @PRINTER)
  175.         (Printer-plots must be sent in BINARY format or the printed
  176.         output may be cut off, distorted and/or spread out over multiple
  177.         pages.)
  178.  
  179. This will create a spooled file for every print or plot job sent by
  180. that node. The files that begin with "R" are printer-plot files
  181. (raster) and the ones beginning with "V" are plot files (vector).
  182. These files, if not deleted, will quickly fill up a harddrive. The
  183. following lines can be added to a batch file to automatically delete
  184. the spooled files (see SAMPLE BATCH FILES: at end of this document):
  185.  
  186.         CD\ACAD11\TEMP             :REM CD\ to the spooler directory.
  187.         DEL R*.*                   :REM Delete all spooled printer-plot files.
  188.         DEL V*.*                   :REM Delete all spooled plot files.  
  189.         CD\
  190.  
  191. If the spool file directory is shared by more than one user, then all
  192. users' plot/printer-plot files will be deleted when any user exits
  193. AutoCAD. To prevent this, change the above command lines as follows:
  194.   
  195.     - Refer to note 6 under "Basic Guidelines" above to get the network
  196.     node. (Select "5. Configure AutoCAD" from the AutoCAD main menu,
  197.     "8. Configure operating parameters", "6. Network node name" and
  198.     read the three character name for this workstation.
  199.     - Change "DEL R*.*" to "DEL R*.TBL" (where "TBL" is the network
  200.     node name specified above)
  201.     - Change "DEL V*.*" to "DEL V*.TBL"
  202.     - Repeat for each node using the appropriate 3 letter network node
  203.     name.
  204.  
  205. NOTE:  When using the AUTOSPOOL feature, "LPT TIMEOUT" and "DESPOOL
  206. TIMEOUT" do not need to be set to 0 (zero) as only complete are files
  207. being transferred across the network. These values can be configured
  208. as required for other applications.
  209.  
  210. 2. If you have a multi-user license, ACAD.EXE will have to be set to
  211. read-only with the DOS ATTRIB command to allow more than one user to
  212. execute the program simultaneously.
  213.  
  214. 3. Each user must have their own configuration directory.  Define
  215. this directory with the DOS environment variable ACADCFG=.  For
  216. example, create a local directory C:\ACAD11 and put "SET
  217. ACADCFG=C:\ACAD11" in the batch file that loads AutoCAD 386-11.  The
  218. first time AutoCAD 386-11 is loaded (or if ACAD.CFG has been
  219. deleted), it will force a system configuration and write ACAD.CFG to
  220. this directory. 
  221.  
  222. 4. To enable the file locking, select "5. Configure AutoCAD" (from
  223. Release 11's opening menu), "8. Configure operating parameters", "11.
  224. Server authorization and file locking" and change this to "ENABLED". 
  225. File locking is automatically enabled if you have a multi-user
  226. license.  AutoCAD 386-11 file locking does not require SHARE.EXE to
  227. be loaded to function.
  228.  
  229. ** Additional Notes on Release 12 (see section below on release 12C2): 
  230. 1. AutoCAD 386 Release 12 has one environment variable available that
  231. can be used to create and send spooled plot files to either a
  232. redirected plotter or printer-plotter automatically. The recommended
  233. configuration is as follows:
  234.  
  235.     1)      Create a directory under the ACAD12 directory called TEMP
  236.             (C:\ACAD12\TEMP). 
  237.     2)      Configure AutoCAD 386-12 to put temporary files and the
  238.             spooled print/plot files there as follows:
  239.         A)       Load AutoCAD 386-12 and enter "CONFIG" from the "Command:
  240.                  " prompt.  
  241.         B)       Select "5. Configure plotter". Keep the same plotters and
  242.                  printers.
  243.         C)       Select "YES" when asked to output to a file. Do this for
  244.                  each plotter device.
  245.         D)       Select "7. Configure operating parameters."
  246.             A) Select "3. Default plot file name", enter "AUTOSPOOL". 
  247.             (NOTE: "AUTOSPOOL" must be in all capital letters.)
  248.             B) Select "4. Plot spooler directory", enter
  249.             "C:\ACAD12\TEMP\".
  250.         E)       Save the changes and exit the configuration menu. 
  251.     3)      If you are using a batch file to load AutoCAD 386-12, put the
  252.             following line in that batch file (otherwise put them in the
  253.             AUTOEXEC.BAT file on each node). (NOTE: the "%%s" MUST BE
  254.             LOWER CASE.)
  255.  
  256.         SET ACADPLCMD=NET  PRINT/BINARY  %%s  LPT2  (Port redirected to
  257.         @PLOTTER)
  258.         NOTE: The ACADPPCMD environment variable is not used in AutoCAD
  259.         386 Release 12.
  260.         
  261. This will create a spooled file for every print or plot job sent by
  262. that node.  All plot files are generated as Vector files and begin
  263. with "V".  These files, if not deleted, will quickly fill up a
  264. harddrive. The following lines can be added to a batch file to
  265. automatically delete the spooled files (see SAMPLE BATCH FILES: at
  266. end of this document):
  267.  
  268.         CD\ACAD\TEMP                 :REM CD\ to the spooler directory.
  269.         DEL V*.*                     :REM Delete all spooled plot files.  
  270.         CD\
  271.  
  272. If the spool file directory is shared by more than one user, then all
  273. users' plot/printer-plot files will be deleted when any user exits
  274. AutoCAD. To prevent this, change the above command lines as follows:
  275.   
  276.     - Refer to note 6 under "Basic Guidelines" above to get the network
  277.     node name. (In Release 12: run "CONFIG" from the "Command: " prompt
  278.     and select "Configure operating parameters", "6. Network node name"
  279.     and read the three character name for this workstation.)
  280.     - Change "DEL V*.*" to "DEL V*.TBL"   (where "TBL" is the network
  281.     node name specified above)
  282.     - Repeat for each node using the appropriate 3 letter network node
  283.     name.
  284.  
  285. NOTE: This configuration is considerably different than that used
  286. with AutoCAD 386-11.  Release 11 allowed only one printer-plotter
  287. and/or one plotter configuration at a time while it provided two
  288. environment variables to allow sending of a printer-plot file to one
  289. network printer and sending a plot file to a different network
  290. device.  Release 12 allows configuration of multiple plotters and
  291. printers while it has one environment variable for sending the plot
  292. file to a network device.  You must select the network device
  293. redirection before sending the plot file - or whenever changing the
  294. plotter device in AutoCAD 386-12.  You can use the "SHELL" command,
  295. run NET, select "Network Disk Drives and Printers" and redirect LPT2
  296. (or whatever port ACADPLCMD is directed to) to the appropriate
  297. network device, before invoking the PLOT command.
  298.  
  299. NOTE:  When using the AUTOSPOOL feature, "LPT TIMEOUT" and "DESPOOL
  300. TIMEOUT" do not need to be set to 0 (zero) as only complete files are
  301. being transferred across the network. These values can be configured
  302. as required for other applications.
  303.  
  304. 2. If you have a multi-user license the following files will have to
  305. be set to read-only with the DOS 
  306. ATTRIB command to allow more than one user to execute the program
  307. simultaneously: ACAD.EXE, *.XMX and *.EXP.
  308.  
  309. 3. Each user must have their own configuration directory.  Define
  310. this directory with the DOS environment variable ACADCFG=.  For
  311. example, create a local directory C:\ACAD12 and put "SET
  312. ACADCFG=C:\ACAD12" in the batch file that loads AutoCAD 386-12.  The
  313. first time AutoCAD 386-12 is loaded (or if ACAD.CFG has been
  314. deleted), it will force a system configuration and write ACAD.CFG to
  315. this directory. 
  316.  
  317. 4.  To enable the file locking, run "CONFIG" from Release 12's
  318. "COMMAND:" prompt, select "7. Configure operating parameters", "12.
  319. Server authorization and file locking" and change this to "ENABLED". 
  320. File locking is automatically enabled if you have a multi-user
  321. license.  AutoCAD 386-11 file locking does not require SHARE.EXE to
  322. be loaded to function.
  323.  
  324. ** Additional Notes on Release 12C2:
  325. AutoCAD 386 Release 12C2 supports printing directly to a DOS Device
  326. parallel port as opposed to outputting directly to the hardware port
  327. (IOBASE 378 in the case of LPT1). Some new features have been added
  328. to the AUTOSPOOL command and it is now possible to pass the name of
  329. the printer/plotter device to the ACADPLCMD environment variable with
  330. "%C" (variables are supported in upper- or lower-case). Refer to the
  331. documentation included with Release 12C2 for more information on
  332. these new features.
  333.  
  334. To use this new feature, rename the printer/plotter devices to the
  335. name of the appropriate DOS Device port name that the device is
  336. available on.  Change the ACADPLCMD variable to the following:
  337.         SET ACADPLCMD=NET  PRINT/BINARY  %%S  %%C 
  338.  
  339. As an example, rename the HPLJ3 printer to "LPT1" and NET USE LPT1
  340. \\SERVER\@HPLJ3;  rename the HP7580 plotter to "COM2" and NET USE
  341. COM2 \\SERVER\@HP7580.  The AUTOSPOOL feature will substitute the
  342. file name for "%S" and the printer/plotter name for %C when it
  343. executes the NET PRINT command. When using the NET PRINT utility, the
  344. file name is displayed under "Comment" on the Printer Queue
  345. Management" screen in the NET menu module.
  346.  
  347. SAMPLE BATCH FILES:
  348. AUTOEXEC.BAT:
  349. PATH=C:\;C:\DOS;\BATCH;C:\UTILITY;C:\LANTASTI  
  350. AEX                         :REM Load netbios drivers. Can be loaded high.
  351. AILANBIO
  352. REDIR CAD1 LOGINS=5         :REM Can be loaded high.
  353. C:\DOS\SHARE  /L:200        :REM Only required on servers; can be loaded high.
  354. LANCACHE CACHE_SIZE=256 TYPE=EMS   :REM 256K cache (using expanded memory).
  355. SERVER                             :REM Server is optional. Can be loaded high.
  356. NET LOGIN \\CAD1 CAD1              :REM Login to servers as needed.
  357. NET USE LPT1 \\CAD1\@PRINTER       :REM Redirect LPT1 to the shared printer-plotter.
  358. NET USE COM2 \\CAD1\@PLOTTER       :REM Redirect COM2 to the shared plotter.
  359. NET LPT TIMEOUT 10      
  360. NET QUEUE HALT \\CAD1 COM1         :REM If a server, halt QUEUE for 
  361.                     mouse/digitizer port.
  362. PROMPT=$P$G
  363. MENU                      
  364.  
  365. ACAD11.BAT:
  366. REM   This batch file has AutoCAD 386-11 installed on a network drive
  367. REM   resource. Disk E: is redirected to that network resource.  
  368. REM   AutoCAD 386-11 is found in E:\ACAD11.
  369. NET LPT TIMEOUT 0                         :REM Set LPT TIMEOUT to zero.
  370. CD\ACAD11\DWG
  371. SET ACADPPCMD=NET PRINT/BINARY %%s LPT1   :REM Printer-plotter command. 
  372. SET ACADPLCMD=NET PRINT %%s COM2          :REM Plotter command.
  373. SET PLPADI=E:\ACAD11\PLPHPLP.EXP          :REM Protected mode plotter driver 
  374. SET DSPADI=C:\VIDEOCFG\DLDVG256.EXP       :REM Protected-mode DLD video driver.
  375. SET DLDCFG=C:\VIDEOCFG\                   :REM DLD configuration file path.
  376. SET ACADPAGEDIR=E:\ACAD11\TEMP            :REM Sets AutoCAD 386 temporary page 
  377.                         file directory.
  378. SET ACAD=E:\ACAD11;E:\ACAD11\SAMPLE;E:\ACAD11\ADS                                  
  379. SET ACADCFG=C:\ACAD
  380. E:
  381. ACAD %1 %2                                :REM Load AutoCAD 386.  
  382. SET ACADCFG=
  383. SET ACAD=                                 :REM Clear environment variables. 
  384. SET ACADPAGEDIR=
  385. SET DLDCFG=
  386. SET DSPADI=
  387. SET PLPADI=
  388. SET ACADPPCMD=
  389. SET ACADPLCMD=
  390. CD\ACAD11\TEMP                            :REM Remove all spooled files.          
  391.                                               
  392. DEL R*.*                                  :REM "DEL R*.TBL" - see text above
  393. DEL V*.*                                  :REM "DEL V*.TBL" - see text above
  394. CD\
  395. NET LPT TIMEOUT 10                        :REM Reset to original value
  396. C:
  397.  
  398. SAMPLE BATCH FILE:
  399. ACAD12.BAT:
  400. REM   This batch file has AutoCAD 386-12 installed on a network drive
  401. REM   resource. Disk E: is redirected to that network resource.  
  402. REM   AutoCAD 386-12 is found in E:\ACAD12.
  403. @ECHO OFF 
  404. NET LPT TIMEOUT 0
  405. E:
  406. CD\ACAD12\DWG
  407. SET ACADPLCMD=NET PRINT/BINARY %%s LPT2   :REM Spooled files go to LPT2
  408. SET DLDCFG=C:\VIDEOCFG\                   :REM Directory for Protected-mode 
  409.                         video driver
  410. SET ACAD=E:\ACAD12\SUPPORT;E:\ACAD12\FONTS;E:\ACAD12\ADS
  411. SET ACADCFG=C:\ACAD                       :REM Configuration file
  412. SET ACADDRV=E:\ACAD12\DRV                 :REM Where ACAD keeps it's driver files
  413. SET ACADPAGEDIR=E:\ACAD12\TEMP            :REM Sets AutoCAD 386 temporary page 
  414.                         file directory
  415. E:\ACAD\ACAD %1                           :REM Loads AutoCAD 386 
  416. SET ACAD=                                 :REM Clear all environment variables
  417. SET DLDCFG=
  418. SET ACADCFG=
  419. SET ACADDRV=
  420. SET ACADCFG=
  421. SET ACADPAGEDIR=
  422. SET ACADPLCMD=
  423. CD\ACAD\TEMP                              :REM Remove all spooled files
  424. DEL V*.TBL 
  425. CD\
  426. NET LPT TIMEOUT 10                        :REM Reset to original value
  427. C:
  428.  
  429. SAMPLE BATCH FILE:
  430. ACAD12C2.BAT:
  431. REM   This batch file has AutoCAD 386-12C2 installed on a network 
  432. REM   drive resource. Disk E: is  redirected to that network resource. 
  433. REM   AutoCAD 386-12C2 is found in E:\ACAD12C2.
  434. @ECHO OFF 
  435. NET LPT TIMEOUT 0
  436. E:
  437. CD\ACAD12\DWG
  438. SET ACADPLCMD=NET PRINT/BINARY %%S %%C    :REM See text for explaination
  439. SET DLDCFG=C:\VIDEOCFG\                   :REM Directory for Protected-mode 
  440.                         video driver
  441. SET ACAD=E:\ACAD12C2\SUPPORT;E:\ACAD12C2\FONTS;E:\ACAD12C2\ADS
  442. SET ACADCFG=C:\ACAD12C2                   :REM Configuration file
  443. SET ACADDRV=E:\ACAD12C2\DRV               :REM Where ACAD keeps it's driver 
  444.                         files
  445. SET ACADPAGEDIR=E:\ACAD12C2\TEMP          :REM Sets AutoCAD 386 temporary page 
  446.                         file directory
  447. E:\ACAD\ACAD %1                           :REM Loads AutoCAD 386 
  448. SET ACAD=                                 :REM Clear all environment variables
  449. SET DLDCFG=
  450. SET ACADCFG=
  451. SET ACADDRV=
  452. SET ACADCFG=
  453. SET ACADPAGEDIR=
  454. SET ACADPLCMD=
  455. CD\ACAD\TEMP                              :REM Remove all spooled files
  456. DEL V*.TBL 
  457. CD\
  458. NET LPT TIMEOUT 10                        :REM Reset to original value
  459. C:
  460.  
  461. VERSION HISTORY
  462. 11/11/92: AutoCAD 386 Release 12 tested for compatibility with
  463. LANtastic v4.1.
  464. 4/11/93: AutoCAD 386 Release 12 tested for compatibility with
  465. LANtastic v5.0.
  466.  
  467. Any questions or suggestions on this bulletin may be mailed to our
  468. offices:
  469. Artisoft, Inc.
  470. 691 East River Road
  471. Tucson, AZ 85704
  472. ATTN: Compatibility Department / AutoCAD Support 
  473.  
  474. VENDOR INFO:
  475. Autodesk, Inc. 
  476. 2320 Marinship Way
  477. Sausalito  CA 94965
  478. (415) 331-0356
  479. (Contact your Autodesk dealer for questions concerning AutoCAD.
  480.  
  481. ARTISOFT, Inc. makes no warranties as to the completeness or accuracy
  482. of this document. LANtastic is a trademark of ARTISOFT, Inc. Brand
  483. names and products are trademarks or registered trademarks of their
  484. respective companies.
  485.  
  486.